MOD-dConn Features
Easy Configuration
Easy to configure MODBUS OPC Server. Simple and easy to use GUI for device and tag definition and viewing real time data from device. Allows declaring OPC Tags in hierarchical manner.
Supports MODBUS Protocol Variants
Supports MODBUS RTU, MODBUS ASCII, MODBUS on RS-232 Serial Port, MODBUS TCP/IP and many others.
Multiple Device Type Support
Allows defining multiple types of device with different register-parameter mapping. User can simultaneously connect different makes of PLC, Energy Meters, SCANNER and other devices on a same channel / port.
Flexible Port /Channels Configuration
Allows setting baud rate, parity and/or start bit on each channel individually. You can also use different variant of MODBUS Protocol on different channels / ports e.g. MODBUS RTU on COM1 channel and MODBUS ASCII on COM2.
Polling Optimization
Allows optimizing reading block of MODBUS Register. This allows muliple tags to be read in a single read command for performance.You can define upto 99 Reading Blocks on a single port / channel.
Device Template Support
You can use pre-built device tample for easy creation of device tags. Allows defining new device tamplates or modifying existing tamplate.
OPC DA 2.0 Interface
MOD-dConn is built using the industry standard Northern Dynamics OPC Server Tool Kit which is compliance tested for OPC DA 2.0. The library has been tested with many third party OPC Client including SCADA/HMI from many vendors.
Tag Scaling
Allows scaling of the value returned by the device. Linear and Square Root type of scaling are supported.
Device Status Tag
Automatically creates a status flag type tag for each defined device which provides Boolean status for communication failure with the device.
Import / Export of Tag
User can export or import Tag Configuration using the CSV file.
Error Diagnostic Support
Automatically creates Error file device communication diagnostic. Time Out, Read / Write and different other types of errors are reported.
System Requirements
PC Hardware: Intel® Pentium® 4 Processor or Equivalent, 256 MB RAM, Minimum 10 MB of available hard disk space for installation. CD-R, Super VGA (1024 ×768), Mouse Pointing Device.
Operating System: Window 2000, Window XP, Window 2003.
|